Microbiological Testing of the Sawyer Mini Filter
The Sawyer Mini Filter was tested for its ability to remove three microorganisms –Raoultella terrigena, Bacillus subtilis, and Micrococcus luteus – using USEPA approvedprocedures. The organisms were added to test water to reach a 107 – 108 initialconcentration. The test water followed the criteria set forth by the USEPA 1987,following the conditions for “test water #3”. All of the three tested filters met the targetreduction of 6 log units, or 99.9999% for all runs. The Sawyer Mini filter meets theUSEPA standard for bacteria.